Menu Close

Polycab - Building Wires

Deekay Electricals are Distributors for Polycab building wires, which generally refers to the electrical wiring carefully placed in a room’s foundation. These wires are what distribute electric power to residential, commercial and industrial buildings.

Request a Quote

Provide us your requirments. Our Experts will get in touch with you shortly.

Building Wires Products Range
Single Core FR-LF Cables
Application

Polycab Single core FR-LF wire is Eco & environment friendly to the environment & suitable for use where high flexibility is of Prime importance. This is also suitable for indoor and outdoor installation in industries, household appliances, power supply for refrigerators, air conditioners and building electrification.

  • Flame Retardant
  • Smooth & glossy surface with enhanced lubrication properties
  • High Insulation Resistance
  • High abrasion Resistance
  • ROHS Complaint
Design
  • Plain annealed bunched circular copper conductor
  • Insulation: Flexible PVC compound
Core Identification

Red, Yellow, Blue, Black, Green (Customized colour can be provided)

Applicable Standard
  • IS 694 : 2010
  • IEC 60332 – 1 : 2004
  • ASTM 2863 : ASTM D2803-17a
Approvals
  • IS 8130: 2013 BIS ISI
  • CE Mark
Cable Characteristics
  • Nominal Voltage (UO/U) : 600/1100 V
  • Max Operating Temperature : 70°C
  • Temperature Range : -15°C to + 70°C
  • Flame Resistant : ASTM D2863
  • Flammability : IEC 60332- 1:2004
  • Minimum Bending Radius : 8D
Nominal Area of Conductor SQ.mm. Max Diameter of each strand Thickness of Insulation (Norn.) mm. Approx. Overall Diameter mm. Current Carrying Capacity* Rating Amps. Resistance (Max.) per Km. @20° Ohms
0.75 24/0.21 0.6 2.5 7

26

1 14/0.31 0.7 2.8 12 18.1
1.5 22/0.30 0.7 3.1 16 12.1
2.5 36/0.30 0.8 3.8 22 7.41
4 56/0.30 0.8 4.4 29 4.95
6 84/0.30 0.8 5.2 37 3.3
10 80/0.41 1.0 5.8 51 1.91
16 126/0.40 1.0 6.8 68 1.21
Single Core FR LF Cables
Single Core FR LF Cables Diagram
Cable Design / Type - FR-LF
Single Core FR-LF-LSH Cables
Application

Polycab Single core FR-LSH unsheathed insulated wire is suitable for residential wiring, either through embedded conduit or on the surface of the wall. The wire has enhanced flame resistant properties and low smoke generation hence it is suitable for use in all high rise buildings, malls and Hospitals.

  • Flame Retardant
  • Low Smoke
  • Smooth & glossy surface with enhanced lubrication properties
  • High Insulation Resistance
  • High abrasion Resistance
  • ROHS Complaint
Design
  • Plain annealed bunched circular copper conductor
  • Insulation: Flexible PVC compound
Core Identification

Red, Yellow, Blue, Black, Green (Customized colour can be provided)

Applicable Standard
  • IS 694:2010
  • IEC 60332-1 : 2004
  • ASTM D2863
  • ASTM D2843-16
  • EC 60754-1 : 2011
Approvals
  • IS 8130: 2013 BIS ISI
  • CE Mark
Cable Characteristics
  • Nominal Voltage (UO/U) : 600/1100 V
  • Max Operating Temperature : 70°C
  • Temperature Range : -15°C to + 70°C
  • Oxygen Index : >29%
  • Smoke Density Rating : Max 60%
  • Acid Gas Generation : Max 20%
  • Flammability : IEC 60332 – 1
  • Minimum Bending Radius : 8D
Nominal Area of Conductor SQ.mm. Max Diameter of each strand Thickness of Insulation (Norn.) mm. Approx. Overall Diameter mm. Current Carrying Capacity* Rating Amps. Resistance (Max.) per Km. @20° Ohms
0.75 24/0.20 0.6 2.5 7

26

1 14/0.30 0.7 2.8 12 18.1
1.5 22/0.30 0.7 3.1 16 12.1
2.5 36/0.30 0.8 3.8 22 7.41
4 56/0.30 0.8 4.4 29 4.95
6 84/0.30 0.8 5.2 37 3.3
10 80/0.40 1.0 5.8 51 1.91
16 126/0.40 1.0 6.8 68 1.21
Single Core FR LF LSH Cables
Single Core FR LF LSH Cables
Cable Design / Type - FR-LF-LSH
Single Core HR-FR-LF Cables
Application

Polycab Single core HR-FR-LF unsheathed wire is suitable for power supply in places where extra fire safety and heat Resistance is required like in high rise buildings, malls, hospitals & subways. This can be used either through embedded conduit or on the surface of the wall.

  • Flame Retardant
  • Smooth & glossy surface With enhanced lubrication properties
  • High Insulation Resistance
  • High abrasion Resistance
  • Rohs Complaint
Design
  • Plain annealed bunched circular copper conductor
  • Insulation: Flexible PVC compound
Core Identification

Red, Yellow, Blue, Black, Green (Customized colour can be provided)

Applicable Standard
  • IS 694 : 2010
  • IEC 60332-1 : 2004
  • ASTM D2863 : 17a
Approvals
  • IS 8130: 2013 BIS ISI
  • CE Mark
Cable Characteristics
  • Nominal Voltage (UO/U) : 600/1100 V
  • Max Operating Temperature : 85°C
  • Temperature Range : -15°C to + 85°C
  • Flame Resistant : ASTM 2863
  • Flammability : IEC 60332 – 1
  • Minimum Bending Radius : 8D
Nominal Area of Conductor SQ.mm. Max Diameter of each strand Thickness of Insulation (Norn.) mm. Approx. Overall Diameter mm. Current Carrying Capacity* Rating Amps. Resistance (Max.) per Km. @20° Ohms
0.75 24/0.20 0.6 2.5 8.4 26
1 14/0.30 0.7 2.8 14.4 18.1
1.5 22/0.30 0.7 3.1 19.2 12.1
2.5 36/0.30 0.8 3.8 26.4 7.41
4 56/0.30 0.8 4.4 34.8 4.95
6 84/0.30 0.8 5.2 44.4 3.3
10 80/0.40 1.0 5.8 61.2 1.91
16 126/0.40 1.0 6.8 81.6 1.21
Single Core HR FR LF Cables
Single Core HR FR LF Cables Diagram
Cable Design / Type - HR-FR-LF
Scroll Top
Deekay Electricals
  • Ostwal Towers, 38, Rattan Bazzar,
    Opp to C1 Police Station Park Town,
    Chennai – 600 003.
Top Quality Electrical Products

Deekay Electricals
  • Ostwal Towers, 38, Rattan Bazzar,
    Opp to C1 Police Station Park Town,
    Chennai – 600 003.
Top Quality Electrical Products