Optical Fiber Cable
Deekay Electricals are now Authorized channel partner for Polycab Optical Fiber Cable. The major advantage is its high transmission capacity i.e. optical fiber can carry information at higher data rates over a very long distance. Since fibers are made of a dielectric material, they are immune to radiated and conducted interference.
Provide us your requirments. Our Experts will get in touch with you shortly.
- Non metallic, anti-buckling FRP Rod as strength member embedded in sheath
- Single loose tube filled with thixotropic jelly and centrally placed in the cable
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-24F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for duct installation
- Used for CATV and other networks
- Light in weight
- Small cable diameter
- Ease of installation
- Available upto 24 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Metallic strength members/Composite fibers/Customized designs/Aramid or Glass Yarns /LSZH/FR PVC.
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as central strength member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z Core wrapped with polyester tape
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and Multimode
OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for blowing in ducts
- Suitable for installation alongside power lines
- Local Loop, metro, long-haul and broadband network
- Light Weight and flexible
- Available upto 144 Fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Metallic CSM/Aramid or Glass Yarns/Rip Cord(s)/FR PVC/LSZH
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as central strength member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z Core wrapped with polyester tape
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and Multimode
OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for blowing in ducts
- Suitable for installation alongside power lines
- Local Loop, metro, long-haul and broadband network
- Light Weight and flexible
- Available upto 144 Fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Metallic CSM/Aramid or Glass Yarns/Rip Cord(s)/FR PVC/LSZH
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Dry core design
- S/Z Core wrapped with water blocking tape
- Outer Sheath with UV Stabilized HDPE compound
- Fiber count 192F-288F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for blowing in ducts
- Suitable for installation alongside power lines
- Local Loop, metro, long-haul and broadband network
- Double layer S/Z stranded
- Available 288 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Wet core(filled with jelly)/Composite fibers/Customized designs/Aramid or Glass Yarns/Rip Cord(s)/FR PVC/ LSZH
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing ribbon fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Inner sheath with UV Stabilized HDPE compound
- Termite resistance Nylon PA-12 orange outer sheath
- Fiber count 48F-576F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for blowing in ducts
- Termite resistance
- Local loop, metro, long-haul and broadband network
- Available upto 576 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Metallic CSM/Aramid or Glass Yarns/Rip Cord(s)
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Metallic, anti-buckling steel wire as strength member embedded in sheath
- Single loose tube filled with thixotropic jelly and centrally placed in the cable
- Electrolyte chrome plated, corrugated steel tape armoured
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-24F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for direct burial and inside duct installation
- ECCS Tape armouring provide excellent protection against rodent
- ECCS Tape armouring provide high crush resistance & tensile strength
- Robust construction
- Light weight to easy installation
- Available upto 24 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Non – Metallic FRP Rods/Composite fibers/Customized designs/Aramid or Glass Yarns/Rip Chord(s)/LSZH/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Electrolyte chrome coated corrugated steel tape armouring
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for direct burial & inside duct installation
- Improves compressive strength and rodent protection
- Local loop, metro, long-haul and broadband network
- Robust construction
- Light weight and flexible
- Available upto 144 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Metallic CSM/Aramid or Glass Yarns/Rip Cord(s)/LSZH/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Inner sheath with UV Stabilized HDPE compound
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Electrolyte chrome coated corrugated steel tape armouring
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for direct burial & inside duct installation
- Improves compressive strength and rodent protection
- It provides additional protection against crush & impact
- Local loop, metro, long-haul and broadband network
- Robust construction
- Available upto 144 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Compos te fibers/Customized designs/Metallic CSM/Aramid or Glass Yarns/Rip Cord(s)/LSZH/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Inner sheath with UV Stabilized HDPE compound
- Glass Yarns (IGFR) as dielectric armour
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for direct burial & ducts installation
- Suitable for installed in areas with high risk of rodent presence
- Dielectric armour provides rodent retardant protection
- Local loop, metro, long-haul and broadband network
- Available upto 144 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Rip Cord (s)
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Single loose tube filled with thixotropic jelly and centrally placed in the cable
- Inner sheath with LSZH compound
- Galvanized steel wire armoured
- Outer sheath with LSZH compound
- Fiber count 2F-24F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for direct burial & inside duct installation
- Improves compressive strength and rodent protection
- Designed for installing in areas where mechanical impact is expected
- Excellent mechanical features
- Available upto 24 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Composite fibers/Customized designs/Aramid or Glass Yarns/Rip Cord (s)/HDPE/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Inner sheath with UV Stabilized HDPE compound
- Galvanized steel wire armouring
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for direct burial & inside duct installation
- Improves compressive strength and rodent protection
- Designed for installation in areas where mechanical impact is expected
- Excellent mechanical features
- Available upto 144 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Metallic CSM/Aramid or Glass Yarns/Rip Cord(s)/LSZH/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Electrolyte chrome coated corrugated steel tape armouring
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 48F-576F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for direct burial & inside duct installation
- Improves compressive strength and rodent protection
- Local loop, metro, long-haul and broadband network
- Robust construction
- Available upto 576 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Metallic CSM/Aramid or Glass Yarns/Rip Cord(s)/LSZH/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Aramid yarns are used as a Peripheral Strength Member (PSM)
- Outer Sheath with UV Stabilized HDPE compound
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for self supporting aerial installation
- Cable can be installed parallel with power lines
- Local loop, metro, long-haul and broadband network
- Dielectric design eliminates grounding issues
- Light weight and flexible
- Available upto 144 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Different Span Lengths/Anti-Tracking sheath/Rip Cord (s)
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Inner sheath with UV Stabilized HDPE compound
- Aramid yarns are used as a Peripheral Strength Member (PSM)
- Outer sheath with UV Stabilized HDPE compound
- Two orange colour marking strips diametrically opposite to each other
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for self supporting aerial installation
- Cable can be installed parallel with power lines
- Local loop, metro, long-haul and broadband network
- Dielectric design eliminates grounding issues
- Light weight and flexible
- Available upto 144 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free) / Composite fibers /customized design / different span lengths / anti tracking sheath / Rip Cord(s)
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Single loose tube filled with thixotropic jelly and centrally placed in the cable
- Galvanized, stranded steel wire used as integrated messenger wire
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-24F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for aerial installation except on power lines
- Messenger wire provides required tensile strength recommended for aerial application
- Light weight cable construction design for ease of handling & installation
- Local loop, metro, long-haul and broadband network
- Available upto 24 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Composite fibers/Customized designs/Aramid or Glass Yarns/LSZH/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Galvanized, stranded steel wire used as integrated messenger wire
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and Multimode
OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for aerial installation except on power lines
- Messenger wire provides required tensile strength recommended for aerial application
- Light weight cable construction design for ease of handling & installation
- Local loop, metro, long-haul and broadband network
- Available upto 144 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Aramid or Glass Yarns/Rip Cord (s)
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Single loose tube filled with thixotropic jelly and centrally placed in the cable
- Aramid yarns as Peripheral Strength Member(PSM)
- Termite resistance Nylon PA-12 orange outer sheath
- Fiber count 2F-24F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for micro duct installation
- All dielectric design
- Light in weight
- Small cable diameter
- Ease of installation
- Available upto 24 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
HDPE/ LSZH /Composite Fibers/Customized designs
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Dry core construction with Water Swellable (WS) yarn
- Termite resistance Nylon PA-12 orange outer sheath
- Fiber count 24F-144F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for blowing in micro ducts
- Local loop, metro, long-haul and broadband network
- Light weight and flexible
- Available upto 144 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Wet core construction/Composite fibers/Customized designs/Aramid Yarns/Rip Cord (s) / HDPE/LSZH
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Tight buffer diameter 900 micron /600 micron
- Tight buffered fiber coated with LSZH comound
- Aramid yarn reinforcement
- Outer jacket with LSZH compound
- Fiber count 1F (SM Fiber G.652D, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for building inter-connections(Campus LAN)
- Fiber patch panels within communications closets
- Link between electronic equipment & fiber patch panels
- Connectorized patchcords
- Gel free design
- Easy to strip & terminate
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Tight buffered coating material PVC/Customized designs/Outer jacket of different colours/ Outer jacket with PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Tight buffered fiber coated with LSZH compound
- Tight buffer diameter 900 micron /600 micron
- Aramid yarn reinforcement
- Outer jacket with LSZH compound
- Fiber count 2F (SM Fiber G.652D, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for building inter-connections(Campus LAN)
- Fiber patch panels within communications closets
- Link between electronic equipment & fiber patch panels
- Connectorized patchcords
- Gel free design
- Easy to strip & terminate
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Tight buffered coating material PVC/Customized designs/Outer jacket of different colours/Outer jacket with PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Fiber embedded in LSZH Sheath between 2 FRP as Peripheral Strength Member(PSM)
- Outer sheath with LSZH compound
- FRP Rod for self supporting
- Fiber count 1F-2F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for outdoor installation
- Suitable for aerial installation, to the end Connectivity up to home
- Easy installation
- Broadband network
- Gel free design
- Available upto 2 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
ARP Rod as a peripheral strength member/Customized designs/Steel Wire as a suspension
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Fiber embedded in LSZH Sheath between 2 FRP Peripheral Strength Member(PSM)
- Outer sheath with LSZH compound
- Fiber count 1F-4F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for indoor installation in any type of civil structures
- Suitable for aerial installation to the end connectivity up to home
- Easy installation
- Broadband network
- Gel free design
- Available upto 4 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
ARP Rod/Steel wire as a peripheral strength member/Composite fibers/Customized designs
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Tight Buffered fiber coated with LSZH compound
- Aramid yarn reinforcement
- Outer jacket with LSZH compound
- Fiber count 2F-24F (SM Fiber G.652D, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for building inter connections
- Easy access to the fiber
- Good bending performance
- High tensile strength & light weight
- Gel free design
- Easy to strip & terminate
- Available upto 24 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Tight buffered coating material PVC/Composite fibers/Customized designs/Different colours of outer jacket/Outer jacket with PVC compound
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Individual fiber jacket outer diameter 2.5 mm (Simplex sub units)
- S/Z core wrapped with water blocking tape
- Aramid yarn reinforcement in sub units
- Outer jacket with LSZH compound
- For easy identification all the tight buffers are colour coated
- Fiber count 4F-12F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Low to medium fiber count requirement
- In-building backbone or horizontal deployment
- Factory floor automation and harsh environment installation
- Office wiring
- Compatible with all standard fiber optic connectors
- Available upto 12 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Composite fibers/Customized designs/Higher fiber count on request/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Single loose tube filled with thixotropic jelly and centrally placed in the cable
- Armouring with aramid reinforced plastic rod
- Glass yarn (IGFR) as a Peripheral Strength Member (PSM)
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-12F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for indoor & outdoor applications
- Ideal for FTTH applications
- High crush resistance
- Excellent rodent proof
- Very light in weight
- Available upto 12 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Composite fibers/Customized designs/Higher fiber count on request/LSZH/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Single loose tube filled with thixotropic jelly and centrally placed in the cable
- Dielectric rigid ceramic armour
- Outer sheath UV Stablized HDPE compound
- Fiber count 2F-12F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for aerial & duct installation
- All dielectric design
- Light in weight
- High tensile & crush resistance
- Rodent proof
- Available upto 12 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
LSZH/FR PVC as an outer jacket /Composite Fibers/Customized designs/Higher fiber count on request
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Fibers with primary coating
- Central stainless steel loose tube, gel-filled design
- Armouring & strain relief made of stainless steel wire
- Outer jacket Nylon PA-12 with extra abrasion resistance
- Fiber count 2F-8F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for indoor & outdoor applications
- Tactical military or civil applications
- High crush resistance
- Excellent rodent proof
- Very light in weight
- Rapid deployment in harsh surroundings
- Available upto 8 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Composite fibers/Customized designs
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non Metallic, anti-buckling two FRP rod as Peripheral Strength Member (PSM)
- Central loose tube containing ribbon fibers and filled with thixotropic jelly
- Cable core dry type wrapped with water blocking tape
- Inner sheath with UV Stabilized HDPE compound
- Loose tube containing single fiber is stranded over inner sheath
- Cable core dry type wrapped with water blocking tape
- Electrolyte chrome coated corrugated steel tape armouring
- Two spring steel wires are embedded in outer sheath
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 48F+8F (SM Fiber G.652D, G.655, G.657 and Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Superior cable design combines ribbon optical fiber and sensory layer content single fiber to provide the signals for IP Cameras, Surveillance devices, Monitoring devices or media convertors via sensory fibers
- Networking security sensors can help prevent physical attacks from internal and external sources, and they also protect against accidental intrusions and the inside threat
- Intrusion proof cabling systems are immune to cable taps
- The product is a carrier-grade product used to meet the high volumes of information coming from the network
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Composite fibers/Customized designs/Aramid or Glass Yarn/Rip Cord(s)
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core dry type
- S/Z core wrapped with water blocking tape
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 6F (SM Fiber G.652D, G.655, G.657 and Multimode OM1,
OM2, OM3 &OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for underground installation on pathways or road
- Robust under all conditions of operation, adjustment, replacement, storage and transport
- Suitable for lightning prone areas
- Better tensile strength
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Wet core construction/Composite fibers/Customized designs/Aramid or Glass Yarns/Rip Cord(s)/ FR PVC/ LSZH
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Non metallic, anti-buckling FRP rod as Central Strength Member (CSM)
- Loose tube containing coloured fibers and filled with thixotropic jelly
- Cable core fully filled with flooding jelly
- S/Z core wrapped with polyester tape
- Inner sheath with UV Stabilized HDPE compound
- FRP Rods armouring as Peripheral Strength Member(PSM)
- Outer sheath with UV Stabilized HDPE compound
- Fiber count 2F-144F (SM Fiber G.652D, G.655, G.657 and
Multimode OM1, OM2, OM3 & OM4)
- Blue
- Orange
- Green
- Brown
- Slate
- White
- Red
- Black
- Yellow
- Viloet
- Pink
- Aqua / Natural


- Suitable for direct burial & inside duct installation
- Improves compressive strength and rodent protection
- Designed for installation in areas where mechanical impact is expected
- Excellent mechanical feature
- Rugged & robust design
- Available upto 144 fibers
- IEC 60794;
- IEC 60793;
- ITU-T Rec. G.650;
- ITU-T Rec. G.652;
- ITU-T Rec. G.655;
- ITU-T Rec. G.656;
- ITU-T Rec G.657 ;
- EN 187000;
- Telecordia GR-20 issue 3rd May, 2008
Dry core construction (Gel free)/Composite fibers/Customized designs/Metallic CSM/Flat FRP/Rip Cord(s)/LSZH/FR PVC
- Operating Temperature : -30˚C to + 70˚C
- Storage Temperature : -30˚C to + 70˚C
- Installation Temperature : -20˚C to + 70˚C
2000 meters ± 10% or as per customer’s requirement


- Fiber Reinforced Plastic (FRP) is manufactured using E-Glass fiber with high heat resistance
- Fiber Reinforced Plastic (FRP) is available in various coatings including EAA and HDPE which allows easy handling
- Di-electric cable composite strength member widely known as FRP/GRP rod is designed to provide excellent strength performance while maintaining high degree of stiffness, preventing cable buckling over its entire service life
- Long continuous standard lengths FRP rod improves yield & productivity on the factory floor. It has an added advantage of high heat resistant property with high torsional strength
- It is most suitable for multi loose tube, uni-tube, slotted core or ribbon cable and is typically used as central or peripheral reinforcement in fiber optic cable
- FRP rods located in the centre of fiber optic cables, combine the high performance properties of glass reinforcements with unique resin formulations to produce a strong and cost-efficient cable reinforcement

- Superior dimensional stability and prevents sagging in aerial installation
- Light weight, excellent tensile strength and high tensile modulus
- Consistent diameter and shape, designed for all-dielectric or metallic cable applications
- Cost effective solution as a strength member
- Provides anti-buckling properties and protection during installation
- Inexpensive way to increase diameter to accommodate designs with high fiber counts increases equipment uptime and productivity
- Long, splice-free lengths and adhesion to up jacketing materials
- Used as central or peripheral reinforcement in fiber optic cable
- Dual Advantage: Reinforcement during installation as well as reduce stress on signal carrying optic fiber/conductor



- Aramid Reinforced Plastic (ARP) manufactured using Aramid yarn and a proprietary resin system to provide low bending radius & good anti-buckling properties with very high modulus
- Aramid Reinforced Plastic (ARP) rods are non-metallic composites designed primarily for use as a central strength member in fiber optic cables
- Aramid Reinforced Plastic (ARP) rods offer high tensile strength & better bending properties with minimum weight
- Aramid Reinforced Plastic (ARP) Rod in addition to high tensile modulus and protection during installation
- It is most suitable for Aerial, FTTH, Drop and Micro duct cables
- These are also ideal for all dielectric cable configurations where placement close to power lines is common

- Light weight, high strength and superior dimensional stability
- Low expansion : ARP has a low coefficient of thermal expansion than steel wire and FRP in a wider temperature range
- Impact and break resistance : ARP has much higher tensile strength
- ARP is non-metallic material not sensitive to electric shock due to lightning rain and other climatic scenarios
- Enables the cable to be compact, aesthetic and flexible, especially for the indoor layouts
- Good flexibility : ARP is flexible and easy to bend and its minimum bending radius is 24 times of the diameter of ARP rod



