Menu Close

Polycab - Rubber Cables

Deekay Electricals are  authorized distributor and dealer for Polycab Cables. Polycab Rubber Cables are used for trailing and flexible supply leads in either single or multi core versions. All cables used in electronics are insulated with materials like plastic or rubber.

Request a Quote

Provide us your requirments. Our Experts will get in touch with you shortly.

Rubber Cable Products Range
Rubber Cable as per IS 9968 Part-1 Power Cable
Construction
  • Conductor: Class 5 annealed tin electrolytic grade copper conductor as per IS 8130
  • Insulation : Special EPR compound equivalent to or better than IE2 as per IS 6380
  • Outer sheath: Special elastomeric compound based on PCP, CSP, NBR – PVC,CPE equivalent to or better than SE4, HOFR as per IS 6380.
  • Rated Voltage: 1 .1 KV
  • AC Test Voltage : 3.0 KV
Working Temperature
  • Fixed Installation : – 40 Deg C to+ 90 Deg C
  • In Operation : – 25 Deg C to+ 90 Deg C

Excellent flexibility, Smooth finish, Enhanced resistance to Ozone, Oxygen, Heat, Solvent, Chemicals and Fire.

Nominal Cross Section Sq.mm Nominal Thicknessof Insulation mm Max Cond. DC Resistance @ 20 Deg C Ohms/Km Max Temp. of the Cond. During Operation Deg C Max Temp. of the Cond. During Shot Circuit Deg C Overall Diameter
1 Core 2 Core 3 Core 4 Core
4 1.0 5.09 90 250 7.8 13.2 13.5 15.4
6 1.0 3.39 90 250 10.0 17.0 18.0 20.4
10 1.2 1.95 90 250 11.8 20.6 22.0 24.2
16 1.2 1.24 90 250 13.6 24.0 25.8 28.4
25 1.4 0.795 90 250 15.7 29.2 31.4 34.2
35 1.4 0.565 90 250 17.4 32.2 34.4 37.6
50 1.6 0.393 90 250 20.2 37.2 39.8 43.6
70 1.6 0.277 90 250 22.5 41.2 44.2 48.6
95 1.8 0.21 90 250 25.4 46.6 50.2 55.2
120 1.8 0.164 90 250 27.6 50.6 54.2 60.0
150 2.0 0.132 90 250 30.4 55.6 59.6 66.0
185 2.2 0.108 90 250 33.4 60.6 65.2 72.5
240 2.4 0.0817 90 250 36.8 67.6 72.8 81.0
300 2.6 0.0654 90 250 40.0 74.6 80.4 89.4
400 2.8 0.0495 90 250 45.0 84.0 90.6 100.8
Polycab Power Rubber Cable
Rubber Cable as per IS 9968 Part 1 Power Cable Diagram
Construction Diagram
Rubber Cable Generally as per IS 9968 Part - 1 Control Cable
Construction
  • Conductor: Class 5 annealed tin electrolytic grade copper conductor as per IS 8130.
  • Insulation: Special EPR compound equivalent to or better than IE2 as per IS 6380.
  • Outer sheath: Special elastomeric compound based on PCP, CSP, NBR-PVC,CPE equivalent to or better than SE4, HOFR as per IS 6380
  • Rated Voltage : 1 .1 KV
  • AC Test Voltage : 3.0 KV
Working Temperature
  • Fixed Installation : – 40 Deg C to+ 90 Deg C
  • In Operation : – 25 Deg C to+ 90 Deg C

Excellent flexibility, Smooth finish, Enhanced resistance to Ozone, Oxygen, Heat, Solvent, Chemicals and Fire.

Nominal Cross Section Sq.mm CORE Nos Nominal Thickness of Insulation mm Max Cond. DC Resistance @20 Deg C Ohms/Km Max Temp. of the Cond. During Operation Deg C Max Temp. of Cond. During Shot Circuit Deg C Overall Diameter mm
1.5 7 1.0 13.7 90 250 14.6
1.5 12 1.0 13.7 90 250 21.0
1.5 24 1.0 13.7 90 250 29.0
2.5 7 1.0 8.21 90 250 16.0
2.5 12 1.0 8.21 90 250 23.0
2.5 24 1.0 5.09 90 250 31.5

2 Core upto 36.

Polycab Control Rubber Cable
Rubber Cable Generally as per IS 9968 Part 1 Control Cable Diagram
Construction Diagram
Rubber Cable Generally as per IS 9968 Part - 1 with Reinforcement
Construction
  • Conductor: Class 5 annealed tin electrolytic grade copper conductor as per IS 8130.
  • Insulation: Special EPR compound equivalent to or better than IE2 as per IS 6380.
  • Bedding: Special elastomeric compound conforming to SE3 I SE4 as per IS 6380.
  • Reinforcement: Anti-torsional reinforcement between bedding and outer sheath.
  • Outer sheath: Special elastomeric compound based on PCP, CSP, NBR-PVC,CPE equivalent to or better than SE4, HOFR as per IS 6380.
  • Rated Voltage 1.1 KV
  • AC Test Voltage : 3.0 KV

Excellent flexibility, Smooth finish, Enhanced resistance to Ozone, Oxygen, Heat, Solvent, Chemicals and Fire.

Reeling & Unreeling application in dry, damp & wet locations as well as outdoors. As universal reeling cables for hoisting, transportation & handling equipment with heavy mechanical stresses, flexible wind energy cable.

Single core upto 400 Sq.mm, Multicore upto 240 Sq.mm, Control core 1.5 Sq.mm to 2.5 Sq.mm upto 36 core.

Polycabe Reinforced Rubber Cable
Rubber Cable Generally as per IS 9968 Part 1 with Reinforcement Diagram
Construction Diagram
Rubber Cable Generally as per IS 9968 Part - 1 Fire Survival Cable
Construction
  • Conductor: Class 1 or 2 annealed tin or plain electrolytic grade copper conductor as per IS 8130.
  • Glass mica tape: Special glass mica tape suitable for 750°C or 950°C.
  • Insulation: Special EPA compound equivalent to or better than IE2 as per IS 6380
  • Bedding : Special Zero halogen elastomeric compound.
  • Fire barrier tape: High temperature resistance glass fibre tape
  • Braiding: Magnetic or non-magnetic metallic wire braiding.
  • Outer sheath: Special zero-halogen LSF (Low smoke & fume) elastomeric compound.
  • Circuit intrigity test at 750°C or 950"C confirming to IEC 60331
  • Smoke density test conforming to AST MD 2843 or IEC 61034
  • Vertical flame spread test confirming to IEC 60332
  • Halogen acid gas test conforming to IEC-60754-1
  • Rated Voltage : 1 .1 KV
  • AC Test Voltage : 3.0 KV

Single core upto 630 Sq.mm, Multicore 2.5 Sq.mm to 240 sq mm.

Polycab Fire Survival Rubber Cable
Rubber Cable Generally as per IS 9968 Part 1 Fire Survival Cable Diagram
Construction Diagram
Scroll Top