Current/Voltage Transducer - E13 (3 Channel)
Features
- Up to 3 measuring inputs: AC currents or AC voltages sine wave-form, arithmetical mean value measurement, calibration to rms with sine wave form.
- Three measuring outputs: DC current signal (load-independent) or DC voltage signal
- Low power consumption / Smaller CT’s & VT’s can be used
- Provision for either snapping the transducer onto top – hat rails or securing it with screws to a wall or panel
- Manufactured in SMD technology/compact & reliable
- Screw terminals suitable for multistrand or thick solid wires.
- Electric isolation between input / output and power supply (3.7 kV) / personnel protection assured
- Electric isolation between channels is 500V
Programable Multifuntion Transducer - M00 (LONbus communication)
Features
- Transfer of data via a LON interface with an FTT-10A transceiver and LONTALK® protocol
- Simultaneous measurement of several variables of a heavy current power system / full supervision of an asymmetrically loaded four-wire power system, rated current 1 to 6 A, rated voltage 57 to 400 (phase to neutral) or 100 to 693 V (phase-to phase)
- For all heavy-current power systems variables
- Input voltage up to 693 V (phase-to-phase)
- High accuracy: U/I/P 0.2% (under reference conditions)
- Up to 4 integrated energy meter, storage every each 203 s, storage for: 20 years
- Windows software with password protection for programming, data analysis, power system status simulation, acquisition of meter data and making settings
- AC/DC power supply / universal
- Provision for either snapping the transducer onto top-hat rails or securing it with screws to a wall or panel
Programable Multifunction Transducer - M01 (Modbus Communication)
Features
- Simultaneous measurement of several variables of a heavy current power system / full supervision of an asymmetrically loaded four-wire power system, rated current 1 to 6 A, rated voltage 57 to 400V (phase to neutral) or 100 to 693V (phase to- phase)
- For all heavy-current power system variables
- Input voltage up to 693 V (phase-to-phase)
- Universal analogue outputs (programmable)
- Transfer of data via MODBUS® interface
- High accuracy: U/I 0.2%, (under reference conditions)
- Universal digital outputs (meter transmitter, limits)
- 4 integrated energy meters, storage every each 203 s, storage for : 20 years
- Windows software with password protection for programming, data analysis, power system status simulation, acquisition of meter data and making settings
- DC-, AC- power pack with wide power supply tolerance /universal Provision for either snapping the transducer onto top – hat rails or securing it with screws to a wall or panel
P18
Features
- Built-in temperature and humidity sensor.
- Calculation of selected physical quantities (dew-point temperature, absolute humidity) – (only P18).
- 2 analog outputs 0/4…20 mA or 0…10 V (P18 option).
- Supply from current loop (P18L).
- Standard d.c. current or d.c. voltage output signal (only P18).
- Storage of measured and calculated maximum and minimum values (only P18).
RISH CON - CA/CV (Dual Output)
Features
- Arithmetical mean value measurement Calibration to RMS with sine waveform (Average Value)
- Accuracy class 0.2 as per International Standard IEC/EN 60 688
- Wide range Auxiliary Power Supply:60-300 V AC/DC or 20-40 VAC/20-60 VDC
- Dual Isolated DC current or DC voltage outputs
- Output Response Time < 250 ms
- Fast and easy installation on DIN RAIL or onto a wall or in panel using optional screw hole bracket
- Connection Terminal: Conventional Screw type
Frequency Transducer Rish Con Hz
Features
- Fully onsite programmable input range.
- Available in Single or Dual output type.
- Onsite selectable output type.(DC current / DC voltage)
- Accuracy class 0.2 ( IEC / EN 60688).
- Seven Segment LCD Display.
- Rs485(Modbus) Communication.
- Wide Auxiliary power supply. Accept any input between 60V-300V AC/DC or 24V-60V AC/DC.
- Output Response Time < 300 ms.
- Fast and easy installation on DIN RAIL or onto a wall or in a panel using optional screw hole bracket.
- Connection Terminal : Conventional Screw type.
Multi Transducer - Rish CON M
Features
- True RMS measurement
- Fully onsite programmable input PT & CT ratio
- Detection and signaling of incorrect phase sequence
- THD Measurement
- Programmable parameters through the RS-485 interface or USB when using the free eCon configuration software
- Onsite selectable analog output range (0…20mA/4…20mA/-20…+20mA)
- Fast and easy installation on DIN RAIL or onto a wall or in a panel using optional screw hole bracket
- Connection Terminal : Conventional Screw type
Power Transducer Rish Con P
Features
- True RMS measurement.
- Fully onsite programmable input voltage range & input current range
- On Site Configurable as Active / Reactive / Apparent Transducer / Phase Angle / Power Factor .
- Onsite selectable output type(DC current / DC voltage).
- Single or Dual output.
- Accuracy Class 0.2 ( IEC / EN 60688) for Power .
- Accuracy Class 0.5 ( IEC / EN 60688) for Phase Angle / Power Factor.
- Seven Segment LCD Display.
- Rs485(Modbus) Communication.
- Wide Auxiliary power supply. Accepts any input between 60V-300V AC/DC or 24V-60V AC/DC.
- Output Response Time < 750 ms standard.
- Fast and easy installation on DIN RAIL or onto a wall
Current/Voltage Transducer - Con I/Con V
Features
- True RMS measurement.
- Fully onsite programmable input voltage range (for RISH CON – V) & Input current range(for RISH CON – I).
- Available in Single or Dual output type.
- Onsite selectable output type (DC current / DC voltage).
- Accuracy class 0.2 (IEC/ EN 60 688) .
- Seven Segment LCD Display.
- Rs485(Modbus) Communication.
- Wide Auxiliary power supply. Accept any input between 60-300VAC/DC or 24-60VAC/DC.
- Output Response Time < 300 ms.
- Fast and easy installation on DIN RAIL or onto a wall or in a panel using optional screw hole bracket.
- Connection Terminal : Conventional Screw type
Programable Multifunction Transducer - M40/M30
Features
- Simultaneous measurement of several variables of a heavy current power system / Full supervision of an asymmetrically loaded four-wire power system, rated current 1 to 6 A, rated voltage 57 to 400 V (phase to neutral) or 100 to 693 V (phase-to phase)
- For all heavy-current power system variables
- 4 analogue outputs
- Input voltage up to 693 V (phase-to-phase)
- Universal analogue outputs (programmable)
- High accuracy: U/I 0.2% and P 0.25% (under reference conditions)
- 4 integrated energy meters, storage every each 203 s, storage for: 20 years
- Windows software with password protection for programming, data analysis, power system status simulation, acquisition of meter data and making settings
- DC-,AC-power pack with wide power supply tolerance / universal
- Provision for either snapping the transducer onto top-hat rails or securing it with screws to a wall or panel
Programable Multifunction Transducer - Mxx Series
Features
- For all heavy-current power system variables
- Up to 6 outputs (2A + 4D or 4A + 2D or 2A or 3A)
- Input voltage up to 693 V (phase-to-phase)
- Universal analogue outputs (programmable)
- Simultaneous measurement of several variables of a heavy current power system / full supervision of an asymmetrically loaded four-wire power system, rated current 1 to 6 A, rated voltage 57 to 400 V(phase to neutral) or 100 to 693 V (phase-to phase)
- High accuracy: U/I 0.2%, Frequency 0.15% and P 0.25% (Under reference conditions)
- Universal digital outputs (meter transmitter, limits)
- Up to 2 or 4 integrated power meters.
- AC/DC power supply/universal (24-80V AC/DC or 85-230V AC/DC)
- Provision for either snapping the transducer onto top – hat rails or securing it with screws to a wall or panel
- Windows software with password protection for programming, data analysis, power system status simulation, acquisition of meter data and making settings.
Current / Voltage Transducer Rish CON CA / CON CV (TRMS)
Features
- True RMS measurement.
- Accuracy class 0.2 as per International Standard IEC/EN 60 688.
- Auxiliary Power Supply: 1)40 V-300 V AC/DC. or 2)24 V-60 V AC/DC.
- Output Response Time < 250 ms.
- Fast and easy installation on DIN RAIL or onto a wall or in panel using optional screw hole bracket.
- Connection Terminal: Conventional Screw type.
- Narrow housing, 22.5 mm / saves space and costs.
Current / Voltage Transducer Rish CON CA / CON CV
Features
- Arithmetical mean value measurement Calibration to RMS with sine waveform (Average Value)
- Accuracy class 0.2 as per International Standard IEC/EN 60 688.
- Auxiliary Power Supply: 1)40 V-300 V AC/DC. or 2)24 V-60 V AC/DC.
- Output Response Time < 250 ms.
- Fast and easy installation on DIN RAIL or onto a wall or in panel using optional screw hole bracket.